How much does it cost to run an air conditioner?
By Sithum Imarsha Last reviewed
A typical 7.1 kW split in the Average climate zone (Adelaide, Perth, Sydney) uses about 1,597 kWh a year on its energy label. That is about $511 a year at 32c/kWh. Flat out it costs about $0.64 an hour to cool, and a typical hour is nearer $0.22.
Your result
Yearly cost from the label
$511a year
1,597 kWh × 32c/kWh
7.1 kW split, Average zone (suggested default)
- Cooling a year
- $190
- Per hour, flat out
- $0.64
- Per typical hour
- $0.22
- Heating a year
- $321
- Per hour, flat out
- $0.65
- Per typical hour
- $0.18
Two methods, side by side. The yearly cost uses the label. The per-hour figures use rated input. A typical hour is our estimate.
Tip. Each degree cooler in summer or warmer in winter adds about 5–10% to energy use. Try 25–27 °C in summer and 18–20 °C in winter.
Fix the highlighted field to update.
How we calculated this
We show two methods side by side and never mix them. The yearly cost is the official label method. The cost per hour comes from the unit's rated input. Official example: a 7 kW unit in Perth uses 315 + 619 = 934 kWh a year. At 29c/kWh that is $271 a year.
Read the label kWh for your zone
The Zoned Energy Rating Label shows a blue cooling kWh and a red heating kWh a year for each of three climate zones. We use the median of the registered models for your size, or the figures you type from your own label.
Cooling 594 kWh · Heating 1,003 kWh · Total 1,597 kWh (Average zone, registry median)
Multiply by your rate
Yearly cost = label kWh × your rate. This is the method the label itself gives. The label assumes a standard pattern of use, so treat it as typical use for your zone.
1,597 kWh × 32c/kWh = $511 a year
Cost per hour, flat out
Rated input kW × rate. Rated input is measured at full capacity: 35 °C outside for cooling, 7 °C for heating. It is the most the unit costs an hour, not a typical hour.
Cooling: 2 kW × 32c/kWh = $0.64. Heating: 2.04 kW × 32c/kWh = $0.65.
Cost per typical hour (Estimate)
Inverters slow down once the room is at the set temperature. At half capacity a median unit draws 37% of its rated input. Our typical load is an engineering estimate from the registry label kWh and reported zone hours we could not confirm: 35% for cooling, 25% to 50% for heating, higher in colder zones.
Cooling: $0.64 × 35% = $0.22. Heating: $0.65 × 27% = $0.18.
| Size | Label kWh a year | Cost a year |
|---|---|---|
| 2.5 kW split | 538 | $172 |
| 3.5 kW split | 701 | $224 |
| 5 kW split | 1,102 | $353 |
| 7.1 kW split | 1,597 | $511 |
| 8 kW split | 1,853 | $593 |
| 10 kW split | 2,319 | $742 |
| 10 kW ducted | 2,455 | $786 |
| 12.5 kW ducted | 3,102 | $993 |
| 14 kW ducted | 3,561 | $1,140 |
| 16 kW ducted | 4,100 | $1,312 |
| 18 kW ducted | 4,930 | $1,578 |
| 20 kW ducted | 5,484 | $1,755 |
Below: the median of the models on the registry file of 17 September 2026, after removing repeats. H / A / C = Hot, Average and Cold zone.
| Size | Input kW (cool / heat) | Cooling kWh (H / A / C) | Heating kWh (H / A / C) |
|---|---|---|---|
| 2.5 kW split | 0.55 / 0.7 | 479 / 170 / 108 | 56 / 368 / 952 |
| 3.5 kW split | 0.87 / 0.9 | 702 / 241 / 152 | 68 / 460 / 1,234 |
| 5 kW split | 1.34 / 1.39 | 1,177 / 402 / 255 | 104 / 700 / 1,922 |
| 7.1 kW split | 2 / 2.04 | 1,733 / 594 / 377 | 140 / 1,003 / 2,796 |
| 8 kW split | 2.36 / 2.42 | 2,040 / 694 / 435 | 162 / 1,159 / 3,218 |
| 10 kW split | 2.71 / 2.87 | 2,464 / 851 / 545 | 208 / 1,468 / 3,992 |
| 10 kW ducted | 2.98 / 2.9 | 2,659 / 910 / 581 | 230 / 1,545 / 4,267 |
| 12.5 kW ducted | 3.68 / 3.68 | 3,461 / 1,184 / 757 | 293 / 1,918 / 5,243 |
| 14 kW ducted | 4.18 / 4.2 | 3,883 / 1,351 / 863 | 333 / 2,210 / 5,979 |
| 16 kW ducted | 4.85 / 4.81 | 4,444 / 1,527 / 976 | 375 / 2,573 / 6,919 |
| 18 kW ducted | 5.61 / 5.41 | 5,493 / 1,913 / 1,227 | 441 / 3,017 / 7,932 |
| 20 kW ducted | 6.12 / 6.17 | 6,436 / 2,190 / 1,427 | 511 / 3,294 / 8,637 |
| Value | Figure | Checked |
|---|---|---|
| Size presets (label kWh, rated input) | Registry medians, 17 Sep 2026 | Official source |
| Climate zone of each capital | Hot: Brisbane, Darwin. Average: Adelaide, Perth, Sydney. Cold: Canberra, Hobart, Melbourne | Official source |
| Typical load | Cooling 35%. Heating 25% Hot, 27% Average, 50% Cold | Estimate |
| Half-capacity draw | 37% of rated input at 50% capacity | Official source |
| Thermostat rule of thumb | 5–10% more energy per °C | Official source |
| State electricity rates | Canstar market average, 4 Sep 2026, except Western Australia (Synergy A1 regulated tariff from 1 Jul 2026) | Dated third-party source, except Western Australia (Official source) |
Sources
- Energy Rating registry: labelled air conditioners (data.gov.au, 17 Sep 2026)
- GEMS Regulator: Zoned Energy Rating Label factsheet (read via the Wayback Machine)
- GEMS Regulator: the new zoned label, for installers (read via the Wayback Machine)
- GEMS Regulator: questions and answers on the zoned label (read via the Wayback Machine)
- Energy Rating: understand the Zoned Energy Rating Label (read via the Wayback Machine)
- energy.gov.au: heating and cooling (read via the Wayback Machine)
- YourHome: heating and cooling (read via the Wayback Machine)
- energy.gov.au: summer energy savings (read via the Wayback Machine)
- Canstar: electricity cost per kWh
- EnergyPlans: solar feed-in tariffs July 2026
- OTTER: Tasmanian feed-in tariffs
- WA legislation: Synergy A1 tariff, charges amendment by-laws 2026 (SL 2026/140)
Capacity is not power use
The size of an air conditioner, like “7 kW”, is its capacity: the heat it moves in or out of the room. The electricity it draws is the rated input, and it is much lower. The median 7.1 kW split on the Energy Rating registry has a rated cooling input of 2.00 kW. A 2.5 kW split draws about 0.55 kW.
That is why “7 kW × your rate” is the wrong cost for a 7 kW aircon. It prices the heat moved, not the power drawn. At the real input of about 2 kW, the same unit costs less than a third of that an hour flat out, and much less on a typical hour.
The label kWh for your zone
The Zoned Energy Rating Label splits Australia into three climate zones. Each zone shows a blue cooling kWh and a red heating kWh a year.
- Hot (modelled on Rockhampton): Brisbane, Darwin.
- Average (modelled on Richmond, northwest of Sydney): Adelaide, Perth, Sydney.
- Cold (modelled on Canberra): Canberra, Hobart, Melbourne.
The official way to estimate a year’s cost is to add the cooling and heating kWh for your zone and multiply by your rate. The label is best used to compare models: a unit with a 20% higher kWh figure will use about 20% more electricity. If you only run it on the hottest or coldest days, you will likely use less than the label says.
The zone mix matters a lot. In the Hot zone, cooling uses about 9 to 12 times the kWh of heating. In the Cold zone it is the other way round: heating uses about 7 to 9 times the kWh of cooling.
Inverters at part load
Most air conditioners sold in Australia are inverters. They run flat out while pulling the room to temperature, then slow down. On the registry’s half-capacity test, a median unit at 50% capacity draws only about 37% of its rated input, and it is about 1.35 times as efficient.
The “Per hour, flat out” figure on this page is the cost of an hour at the rated input. A typical hour costs far less. Our “typical hour” uses an estimated average load, shown under “How we calculated this”. Treat it as an estimate, not a measurement.
Watch out for
- Single-duct portable air conditioners get 0 stars. The regulator says they have no overall cooling effect on the room.
- Old labels and new labels are not comparable. Old-label stars cannot be converted to new-label stars.
- Time-of-use rates. This calculator uses one flat rate. On a time-of-use plan, evening use hits peak rates, so your real cost can be higher. Solar you use yourself will make it lower.
Reverse cycle heating vs a plug-in heater
Reverse cycle air conditioners move heat instead of making it, so they use far less power than a plug-in heater for the same warmth. To compare the two, use the heater running cost calculator.
What a 2.5 kW split costs to run
A 2.5 kW split in the Average zone uses about 538 kWh a year on its label: about $172 a year at 32c/kWh. Flat out it costs about $0.18 an hour to cool. The table of every size in "How we calculated this" uses your own settings.
- The median 2.5 kW split draws 0.55 kW at full cooling. Its EER is 4.63, against 3.54 for the median 7.1 kW split, so small units move more heat for each kWh. (Energy Rating registry ac_2026_09_17.csv, deduplicated medians)
- In the Average zone a typical 7.1 kW split uses about 3.5 times the cooling kWh of a 2.5 kW (594 against 170 a year). (Energy Rating registry ac_2026_09_17.csv, deduplicated medians)
- The government does not endorse a sizing tool. Room size, windows and their direction, insulation and shading all matter. A licensed installer can advise. (GEMS Regulator, questions and answers on the zoned label, Q7; Not yet checked)
Questions
How much does it cost to run a split system per hour?
A 7.1 kW split costs about $0.64 an hour flat out cooling at 32c/kWh, and nearer $0.22 in a typical hour, when it is not running flat out. Smaller units cost less.
Does heating or cooling cost more?
It depends on where you live. For a 7.1 kW split in the Average zone the label gives $190 a year for cooling and $321 for heating. In the Cold zone it is $121 and $895.
How do I work out my aircon’s running cost?
Add the blue (cooling) and red (heating) kWh for your zone on the energy label, then multiply by your electricity rate. Type your label figures into the calculator to do this for your own model.
Is the kWh on the label accurate for my home?
It is a standard estimate for comparing models. Heavy users will use more. People who only run it on very hot or very cold days will use less.
Which climate zone am I in?
Brisbane and Darwin are Hot. Sydney, Adelaide and Perth are Average. Melbourne, Canberra and Hobart are Cold. For other places, use the postcode lookup in the Energy Rating Calculator.
How many kW does a 7 kW air conditioner use?
About 2 kW of electricity at full cooling power. 7 kW is the heat it moves, not the power it draws. The median 7.1 kW split on the registry has a rated input of 2.00 kW.
Do more stars really save money?
Yes, between units of a similar size. Each extra star means the seasonal efficiency is 1.0 higher.
Can I compare old-label stars with new-label stars?
No. The old and new labels use different tests, and their stars cannot be converted.